Qureshi University, Advanced courses, via cutting edge technology, News, Breaking News | Latest News And Media | Current News
admin@qureshiuniversity.com

Apply for Academic Admission | Academic Guide | Administrative law | About the Founder | Aircraft | Aviation World | Ambassadors | Accreditation | A to Z Degree Fields | Books | Blog | Catalog | Calendar | Collaboration | Colleges | Complaint | Contact Us | Continents/States | Construction | Contracts | Courses | Data Center | Doctor Consultation | Distance Education | Education materials | Equipment | Emergency | Emergency call centers | Economy and Budget | Examinations | English Editing Service | Fabrics | Forms | Faculty | Facilities | Fuel | Governor | Glossary | Grants | Hardware | Hardware Resources | Helicopters | Hostels | Honorary Doctorate degree | Human Services | Human Resources | Internet Education | Inspections | Internet | Intellectual Property | Investment | Instructors | Internship | Job Openings | Journal | Login | Lecture | Librarians | Languages | License/Permit/Registration | Medical Emergency | Manufacturing | Materials | Mentor | Military Equipment Guide | Movies | Money transfer(Pay Now) | Membership | North America | Non-Emergency Services | Observers | Planet Earth | Proposals | Publication | Professional Examinations | Professions | Paraprofessional | Profile | Progress Report | Recommendations | Ration food and supplies | Research Grants | Research | States | State Directories | Students login | School | Search | Software | Seminar | Study Center/Centre | Sponsorship | Submit an Issue | Surveillance | Team | Tutoring | Thesis | Universities | Universe & Space | Vehicles | Work counseling | World economy

Cable
A cable is most often two or more wires running side by side and bonded, twisted or braided together to form a single assembly, but can also refer to a heavy strong rope. In mechanics cables, otherwise known as wire ropes, are used for lifting, hauling and towing or conveying force through tension. In electrical engineering cables are used to carry electric currents. An optical cable contains one or more optical fibers in a protective jacket that supports the fibers.

Electric cables discussed here are mainly meant for installation in buildings and industrial sites. For power transmission at distances greater than a few kilometres see high-voltage cable, power cables and HVDC.

Contents
1 History
2 Electrical cables
    2.1 Cables and electromagnetic fields
    2.2 Fire protection
    2.3 Electrical cable types
3 Application
4 See also
5 References
6 Further reading
7 External links

History

Ropes made of multiple strands of natural fibers such as hemp, sisal, manila, and cotton have been used for millennia for hoisting and hauling. By the 19th century, deepening of mines and construction of large ships increased demand for stronger cables. Invention of improved steelmaking techniques made high-quality steel available at lower cost, and so wire ropes became common in mining and other industrial applications. By the middle of the 19th century, manufacture of large submarine telegraph cables was done using machines similar to those used for manufacture of mechanical cables.

In the 19th century and early 20th century, electrical cable was often insulated using cloth, rubber and paper. Plastic materials are generally used today, except for high-reliability power cables.

Electrical cables

Electrical cables may be made more flexible by stranding the wires. In this process, smaller individual wires are twisted or braided together to produce larger wires that are more flexible than solid wires of similar size. Bunching small wires before concentric stranding adds the most flexibility. Copper wires in a cable may be bare, or they may be plated with a thin layer of another metal, most often tin but sometimes gold, silver or some other material. Tin, gold, and silver are much less prone to oxidation than copper, which may lengthen wire life, and makes soldering easier. Tinning is also used to provide lubrication between strands. Tinning was used to help removal of rubber insulation. Tight lays during stranding makes the cable extensible (CBA - as in telephone handset cords).

Cables can be securely fastened and organized, such as by using trunking, cable trays, cable ties or cable lacing. Continuous-flex or flexible cables used in moving applications within cable carriers can be secured using strain relief devices or cable ties.

At high frequencies, current tends to run along the surface of the conductor. This is known as the skin effect.

Cables and electromagnetic fields

Any current-carrying conductor, including a cable, radiates an electromagnetic field. Likewise, any conductor or cable will pick up energy from any existing electromagnetic field around it. These effects are often undesirable, in the first case amounting to unwanted transmission of energy which may adversely affect nearby equipment or other parts of the same piece of equipment; and in the second case, unwanted pickup of noise which may mask the desired signal being carried by the cable, or, if the cable is carrying power supply or control voltages, pollute them to such an extent as to cause equipment malfunction.

The first solution to these problems is to keep cable lengths in buildings short, since pick up and transmission are essentially proportional to the length of the cable. The second solution is to route cables away from trouble. Beyond this, there are particular cable designs that minimize electromagnetic pickup and transmission. Three of the principal design techniques are shielding, coaxial geometry, and twisted-pair geometry.

Shielding makes use of the electrical principle of the Faraday cage. The cable is encased for its entire length in foil or wire mesh. All wires running inside this shielding layer will be to a large extent decoupled from external electric fields, particularly if the shield is connected to a point of constant voltage, such as earth. Simple shielding of this type is not greatly effective against low-frequency magnetic fields, however - such as magnetic "hum" from a nearby power transformer. A grounded shield on cables operating at 2.5 kV or more gathers leakage current and capacitive current, protecting people from electric shock and equalizing stress on the cable insulation.

Coaxial design helps to further reduce low-frequency magnetic transmission and pickup. In this design the foil or mesh shield has a circular cross section and the inner conductor is exactly at its center. This causes the voltages induced by a magnetic field between the shield and the core conductor to consist of two nearly equal magnitudes which cancel each other.

A twisted pair has two wires of a cable twisted around each other. This can be demonstrated by putting one end of a pair of wires in a hand drill and turning while maintaining moderate tension on the line. Where the interfering signal has a wave length that is long compared to the pitch of the twisted pair, alternate lengths of wires develop opposing voltages, tending to cancel the effect of the interference.

Fire protection

In building construction, electrical cable jacket material is a potential source of fuel for fires. To limit the spread of fire along cable jacketing, one may use cable coating materials or one may use cables with jacketing that is inherently fire retardant. The plastic covering on some metal clad cables may be stripped off at installation to reduce the fuel source for fires. Inorganic coatings and boxes around cables safeguard the adjacent areas from the fire threat associated with unprotected cable jacketing. However, this fire protection also traps heat generated from conductor losses, so the protection must be thin.

There are two methods of providing fire protection to a cable:

Insulation material is deliberately added with fire retardant materials

The copper conductor itself is covered with mineral insulation (MICC cables)

Electrical cable types

Basic cable types are as follows:

Shape

Ribbon cable

Construction

Based on construction and cable properties, they can be sorted into the following:
    Coaxial cable
    Mineral-insulated copper-clad cable
    Twinax cable
    Flexible cables
    Non-metallic sheathed cable (or nonmetallic building wire, NM, NM-B)[1]
    Metallic sheathed cable (or armored cable, AC, or BX)[1] Multicore cable (consist of more than one wire and is covered by cable jacket)
    Shielded cable
    Single cable (from time to time this name is used for wire) Twisted pair
    Twisting cable
Special

Arresting cable
Bowden cable
Heliax cable
Direct-buried cable
Heavy-lift cable
Elevator cable

Application

Audiovisual cable
Bowden cable for bicycle
Communications cable
Computer cable
Mechanical cable
Sensing cable[2]
Submersible cable
Wire rope (wire cable)

See also

For transmission see: Power cable, High-voltage cable and HVDC
Cable dressing
Cable gland
Cable harness
Cable lacing
Cable length
Cable management
Cable modem
Cable reel
Cable television
Cable tray
Category 5 cable
Category 6 cable
Category 7 cable
Circuit integrity
Copper wire and cable
Cross-linked polyethylene
DOCSIS
Electrical connector
Electrical wiring
Extension cable
International Cablemakers Federation
Over/under cable coiling
Polyvinyl chloride
Portable cord
Power cable
Profibus
Submarine communications cable
Submarine power cable
Steel Wire Armoured (SWA) Cable
SY control cable
Tensile structure
Transmission line
Wire
Wire rope



6 inch (15 cm) outside diameter, oil-cooled cables, traversing the Grand Coulee Dam throughout. An example of a heavy cable for power transmission.



Fire test in Sweden, showing rapid fire spread through burning of cable jackets. Of great importance for cables used in installations.



500,000 circular mil (254 mm2) single conductor power cable



Coaxial cable.



Twisted pair cabling



A 250V, 16A electrical cable on a reel.